An empty dehumidifier bucket can mean the room is already below the set point, water is leaving through a hose, or the machine is not removing moisture. Check actual relative humidity, room temperature, airflow, bucket seating, and drainage before deciding that the compressor has failed.

Start with a separate humidity reading
Place a hygrometer near the dehumidifier, but not directly in its warm exhaust. Compare that reading with the selected humidity. ENERGY STAR notes that a built-in humidistat cycles the unit once the desired level is reached; a machine set to 50% may run its fan or cycle without filling the bucket when the room is already near or below 50%.
Give the reading time to settle after moving the hygrometer. If the room is clearly damp and remains well above the set point for several hours, continue through the checks. A musty smell alone is not a measurement, and a plumbing or building leak must be repaired rather than hidden by continuous dehumidification.

Check temperature before judging capacity
Portable refrigerant dehumidifiers remove less water in cool rooms. ENERGY STAR warns that frost can form on condensing coils below about 65°F (18°C), causing repeated cycling without effective moisture removal unless the model is designed for lower temperatures. If frost is visible through a normal vent, switch the unit off and allow it to defrost; do not pry ice from the coil.
Use the operating range in the model manual. A basement near the lower limit may need a low-temperature-rated unit or a different moisture strategy. Do not add a space heater directly beside the appliance as a shortcut.

Restore airflow without opening the cabinet
Close exterior windows and doors while testing, and leave the clearance required by the manual around the inlet and outlet. Move curtains, laundry, and furniture away. Switch off and unplug the unit before cleaning an accessible filter. Reinstall it only when fully dry and correctly seated.
Stop immediately for a burning smell, unusual grinding, overheating, smoke, or damaged cable. Electrical Safety First advises switching off and contacting the retailer or manufacturer for those conditions. Do not remove the cabinet or work on refrigerant components.

Find where the water is supposed to go
If a gravity hose is attached, the bucket may remain empty by design. GE notes that connecting the drain hose routes collected water away instead of into the bucket. Confirm the hose runs continuously downhill, is not kinked, and ends above standing water. Follow the exact model instructions; a pump hose and a gravity hose are not interchangeable.
For bucket mode, remove and reseat the bucket. Many units will not operate correctly unless its safety switch is engaged. Check that the float moves freely without forcing it. Never bypass the switch or tape it down.
Use one controlled test, then stop guessing
GE recommends a simple reset on applicable models: disconnect power for 30 seconds, reconnect, select the controls, and observe. After confirming high room humidity, suitable temperature, clear airflow, correct bucket or hose setup, and a clean filter, allow the manual's expected test period.
If humidity stays high and no water reaches either bucket or drain, use warranty or manufacturer service guidance. Repeating resets will not repair a sealed refrigeration fault. Record room humidity, temperature, settings, and whether the fan or compressor sound starts; that information is more useful to support than “it runs but does nothing.”